- Offline key sinutrain for sinumerik operate 4.4 install#
- Offline key sinutrain for sinumerik operate 4.4 software#
- Offline key sinutrain for sinumerik operate 4.4 password#
- Offline key sinutrain for sinumerik operate 4.4 Pc#
- Offline key sinutrain for sinumerik operate 4.4 license#
For OPC UA it is required that your PC trusts the Siemens certificate issued by your controller. Note: Both programs components and run on newer Microsoft Windows x86 and 圆4 OSes (>= Windows 7). You can use our tool Device Port Scanner to check if your controller is reachable via this port. Make sure that TCP Port 4840 is opened in your Firewall.
Offline key sinutrain for sinumerik operate 4.4 software#
SOFTWARE SETUP & USAGE (PC) Download Sinumerik_840D_828D_OPC_UA.zip and extract all files to a folder on your PC. You can also define: Group StateRead StateWrite FrameRead FrameWrite SeaRead SeaWrite TeaRead TeaWrite ToolRead ToolWrite DriveRead DriveWrite Access Right Status data - NC, channel, axis, read Status data - NC, channel, axis, write Zero offsets, read Zero offsets, write Setting data, read Setting data, write Machine data, write Machine data, write Tool and magazine data, read Tool and magazine data, write Drive data, read Drive data, write of 10Ħ GudRead GudWrite PlcRead PlcWrite RandomRead User data, read User data, write PLC, read PLC, write Random (and ReadVar method), read RandomWrite Random (and WriteVar method), write Save file UserDataBase.xml and start the controller. SinuReadAll and SinuWriteAll enable the user to read and write all items. Membership to groups define the rights for the user.
Offline key sinutrain for sinumerik operate 4.4 password#
of 10ĥ Note that the PASSWORD entry is automatically removed by miniweb.exe after startup. To add user OpcUaClient with Password OpcUaClient add the following section to the end of the file before. All GROUP NAME Tags have an additional A1= entry with an encrypted value which are automatically created by the miniweb OPC UA server. User information is defined between tags. At a real controller it s not possible to directly add or change users To do so proceed as follows. Do NOT close this window! CONFIGURE USERS When you run the free version of SinuTrain for SINUMERIK Operate V4.7 you do NOT have access to the OPC UA configuration soft key at the controller. If configured correctly on startup of the machine now an additional command line window opens that shows details about the activities of miniweb.exe. At the end add: PROC100= image:="c:\siemens\sinutrain\sinumerik CNC-SW 840D sl 4.7 SP3 HF1\hmi\siemens\sinumerik\hmi\miniweb\release\miniweb.exe", process:=miniwebserver, cmdline:=".\system.\still contains the additional process. Open file C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\user\sinumerik\hmi\cfg\systemconfiguration.ini with a text editor. This user is administrator of the OPC UA server and has the right to read and write all items at the controller. Add file UserDataBase.xml (from the.zip archive) to directory C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\siemens\sinumerik\hmi\miniweb\System\UserDataBase\ File UserDataBase.xml contains entries for OPC UA user OpcUaClient with Password OpcUaClient. Copy ALL files from folder C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\siemens\sinumerik\hmi\template\cfg\miniweb\ to folder C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\user\sinumerik\hmi\miniweb\cfg\ Open UAApplication.xml with a text editor and replace all localhost entries in this file with the IPv4 address of your PC.
Offline key sinutrain for sinumerik operate 4.4 license#
Click - > -, enter OPC, activate the license and click. Lathe with driven tool, it is recommended NOT to use the DEMO-Lathe device. Start SinuTrain and create one new machine f.i. If you accept all default settings you are able to use the paths mentioned below.
Offline key sinutrain for sinumerik operate 4.4 install#
Download and install SinuTrain for SINUMERIK Operate V4.7 Ed.2 - Basic. You have to register a free account to be able to download the program.
CONTROLLER SETUP (SINUTRAIN) OPC UA setup on the free version of SinuTrain for SINUMERIK Operate V4.7 Ed.2 differs a bit from the procedure on a real controller but exactly works in the same way. \siemens\sinumerik\hmi\template\cfg\miniweb\ Restart the controller. If files are missing, copy them to this directory from. \user\sinumerik\hmi\miniweb\cfg\: AddressModeller.xml, OPC_UAApplication.xml, SinumerikOemConfiguration.xml and TraceConfig.xml. of 10ģ Make sure that the following files are in folder. \siemens\sinumerik\hmi\miniweb\system\ and verify that it contains file UserDataBase.xml. With Windows Explorer navigate to folder. Important note: Please ensure that the date and time on your HMI is correct, otherwise certificate based OPC UA authentication does not work! Shut down the controller and start it in service mode without HMI. For testing it is also recommended to use OpcUaClient. Enter and confirm the password for this user (3). Enter 4840 in field Port (2) Enter a username for the Administrator (2) of the OPC UA server on the controller, for testing it is recommended to use OpcUaClient. 2 Start the OPC UA configuration in area ->-> FIG 2: Configure OPC UA IP Address is automatically set according to the HMI configuration, -X130 for NCU and PPU Local Area Connection 2 for PCU 50.